This battery was purchased 2 years ago however has undergone minimal cycles it has been kept in a clean dry environment and charged up intermittently to ensure performance
The EnergyCell PLC (pure-lead carbon) uses pure lead plate construction combined with carbon additives to obtain maximum cycle life, float life, shelf life (18 months at 25°C), andPSoC operation. The PLC is ideally suited for the three primary applications where OutBackinverters are used: Off-Grid, Grid-Tied Battery Backup, and Grid-Tied Self Consumption renewable energy power demands.
3,000 cycles at 50% DOD.
Pure lead extends the life of the battery versus traditional VRLA and allows for increased float capability for backup applications
Advanced carbon technology reduces the effect of sulfation and is compatible with Partial State of Charge (PSoC) operation
Fast recharge—90% SoC in 1.5 hours 2.
EASY-TO-INSTALL AND MAINTAIN
PLC technology means 99% gas recombination efficient, no periodic watering of cells, no re-torquing of terminal connections, and no equalization charge under standard operating conditions
At end of life, lead acid batteries are 96% recyclable
Optimized to work seamlessly with OutBack power conversion equipment
EnergyCell Models: 200PLC
Cells Per Unit 6
Nominal Voltage 12VDC
Cycle Life (50% DOD, 1.75VPC) 3000
Absorb Voltage (25°C)1 14.1VDC
Absorb Time2 6hrs (0.15C)
Float Voltage (25°C)1 13.5VDC
Float Time 6hrs (0.15C)
Equalize Voltage and Charge Frequency 14.1
Re-Bulk Voltage3 14.1
Re-Float Voltage3 13.5
Maximum Charge Current (Per Battery) 0.25C
Operating Temperature Range
(w/Temperature Compensation) Discharge: -40 to 149°F (-40 to 65°C) Charge: 5 to 140°F (-15 to 60°C) Storage: -4 to 104°F (-20 to 40°C)
Optimal Operating Temperature Range 68 to 86°F (20 to 30°C)
Temp-Comp Factor (Charging) -4mV per °C per cell (2V)
Self-Discharge Time Batteries can be stored up to 24 months at 25°C (77°F) before a freshening charge is required. For higher temperatures the time interval will be shorter
Terminal Type T11
Terminal Hardware Initial Torque 11 to 14.7Nm)
Weight (lb/kg) 130 / 59
Dimensions H x D x W (in/cm)4 12.6 x 22 x 4.92 / 32 x 55.88 x 12.50
Low self-discharge
Oxygen recombination efficiency: ≥ 97%
3D plate structure, optimal plate design provides better performance for high power output than other EnergyCell models
VRLA maintenance free battery type
UL94-V0 flame-retardant jar container